 Inductive Ring Sensor
Ring Sensing Head for Detecting Moving Minute Metallic Objects
Detects moving metallic objects of any shape anywhere in the ring. Sensor Heads with 10-mm to 100-mm diameters available. Incorporates a 40-ms OFF-delay timer. Amplifier Unit with DIN-track mounting hooks available.
F2LP-W
Ordering Information
Sensor Heads
Sensor Head (non-shielded) 10 dia. Min. object size 0.3 dia. x 0.5 mm steel rod F2LP-W10M Model
20 dia.
0.3 dia. x 1.0 mm steel rod
F2LP-W20M
50 dia.
2.0-dia. steel ball
F2LP-W50M
75 dia.
2.5-dia. steel ball
F2LP-W75M
100 dia.
3.0-dia. steel ball
F2LP-W100M
Amplifier Unit
Power supply 120/240 VAC, 50/60 Hz Relay: DC Solid-state: Output SPDT, 2 A, 250 VAC or 3 A, 30 VDC Photocoupler 100 mA max. Model F2LP-WK4-US
1
F2LP-W
F2LP-W
Application Examples
Counting Falling Screws Tank F2LP-WK4-US
CQM1 F2LP-W50M
Specifications
Ratings/Characteristics
Sensor Units
Model Sensing area Sensing objects (see note 1) Min. object size Ambient temperature Ambient humidity Insulation resistance Dielectric strength Vibration resistance Shock resistance Cable (see note 2) Weight Enclosure rating Material Case Sensing surface Note: F2LP-W10M 10 dia. 0.3 dia. x 0.5 mm steel rod F2LP-W20M 20 dia. 0.3 dia. x 1.0 mm steel rod F2LP-W50M 50 dia. 2.0-dia. steel ball F2LP-75M 75 dia. 2.5-dia. steel ball F2LP-W100M 100 dia. 3.0-dia. steel ball
Ferrous or non-ferrous moving metal object (Sensitivity lowers with non-ferrous metals).
Operating: -25C to 70C (with no icing) Operating: 35% to 95% 50 M min. 1,000 VAC for 1 min. Head case and shield (0 V) are electrically connected. Head case and shield (0 V) are electrically connected.
Durability: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, Z directions Durability: 500 m/s2 (approx. 50G) for 3 times each in X, Y, Z directions 3 m (high-frequency coaxial cable) Approx. 80 g IEC IP67 Heat-resisting ABS resin Aluminum diecast Approx. 220 g Approx. 430 g Approx. 800 g Approx. 1,200 g
Heat-resisting ABS resin
1. The moving speed is based on the natural fall of objects from a height 10 cm above the Sensor. 2. The cable can be shortened or connected to another cable, as long as the total length of the cable is from 1.5 to 10 m. Use the following cables for extension: F2LP-W10M, F2LP-W20M: Electrostatic capacity 97 nF/km; characteristic impedance 50 2 F2LP-W-50M, F2LP-W75M, F2LP-W100M: Electrostatic capacity 100 nF/km; characteristic impedance 50 2
2
F2LP-W
Amplifier Unit
Supply voltage Power consumption Sensitivity adjustment Timer Sensing interval Control output DC solid-state Relay DC solid-state Relay DC solid-state Relay 120/240 VAC 15%, 50/60 Hz 3 VA max. Selector and variable resistor Normal or 40-ms OFF delay. (selectable) One-shot, 40 ms (fixed)
F2LP-W
Normal: 75 ms max.; OFF-delay: 125 ms max. (Minimum sensing objects can be detected at intervals specified. Larger objects need longer intervals.) 75 ms max. (See note for DC solid-state sensing interval.) 100 mA, 40 VDC max. photocoupler output; residual voltage: 2 V max. (Refer to Engineering Data.) Resistive load of 2 A at 250 VAC or 3 A at 30 VDC Can be connected to F2LP-WjM Sensors with a diameter of 10, 20, 50, 75, or 100 (switchable).
Compatibility with Sensor Heads with different diameters Compensation for cord length Output form Indicators Ambient temperature Ambient humidity Insulation resistance
Switch setting NO or NC (switchable) Power and operation Operating: -10C to 55C (with no icing) Operating: 35% to 85% 50 M min. (at 500 VDC) between all live terminals and non-current carrying bare metal parts, and between all primary terminals (for power supply) and all secondary terminals (for non-contact output and Sensor) 1,500 VAC, 50/60 Hz for 1 minute between all live terminals and non-current carrying bare metal parts, between all primary terminals (for power supply) and all secondary terminals (for non-contact output and Sensor), and among all contact output terminals Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours in X, Y, Z directions respectively Destruction: 100 m/s2 (approx. 10G) for 3 times in X, Y, Z directions respectively IEC IP30 Approx. 300 g
Dielectric strength
Vibration resistance Shock resistance Enclosure ratings Weight
Engineering Data
Object Size vs. Falling Speed of Object (Typ.)
F2LP-W10M F2LP-W20M
Iron
Speed (V m/s)
Object
Height (m)
Height
Speed (V m/s)
Iron
Aluminum
Aluminum
Object size (dia. x 0.5 mm)
Object size (dia. in 1 mm)
Height (m)
Object
Height
3
F2LP-W
F2LP-W50M
Iron Brass
F2LP-W
F2LP-W75M
Object
Height
Iron Brass Object
Height
Speed (V m/s)
Speed (V m/s)
Height (m)
Sensing area
Sensing area
Object size (dia. in mm)
Object size (dia. in mm)
Residual Load Voltage Characteristics (Typ.)
F2LP-W100M
Iron Brass Object Height
F2LP-WK4-US
Speed (V m/s)
Object size (dia. in mm)
Load voltage (v)
Height (m)
Load current (mA)
Operation
Amplifier Unit
POWER indicator: Lit when power is on. OPERATION indicator: Lit when sensing objects. Sensitivity selector Timer mode selector (see note 1) Output mode selector (see note 2) Frequency selector: If induction or other mutual interference is experienced when using more than one Sensor, set the Sensor to different frequencies.
Sensor selector: F2LP-W10M, F2LP-W20M: Select dia. of 10 to 20 F2LP-W50M, F2LP-W75M, F2LP-W100M: Select dia. of 50 to 100 Compensation selector: Select the position according to the cable length. When cutting or extending the cable, the length should be between 1.5 m and 10 m. Note:
240 VAC 120 VAC
--US
1. Timer mode selector: NORM: No timer; TIMER: OFF-delay transistor output (40 ms) 2. Output mode selector: NO: Both transistor output and relay output ON when sensing objects; NC: Transistor output OFF and relay output ON when sensing objects
Sensitivity adjustor
4
Height (m)
F2LP-W Timing Chart
Sensing Output mode Object present No object NO NC OFF-delay NORMAL ON OFF ON OFF
F2LP-W
Timer mode Transistor output
Relay output OPERATION indicator POWER indicator
Note:
Lit Not lit Lit Not lit
1. Relay outputs are ON when objects are sensed (when objects pass through the Sensor head) 2. Each relay output is ON for 40 ms minimum regardless of the position of the timer mode selector.
A: 40 ms (OFF-delay) B: 40 ms (per detection)
When power is off
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Sensor Heads
F2LP-W10M
10-dia. hole
F2LP-W20M
20-dia. hole 4.1 dia., one-conductor coaxial cable (length: 3 m) Two, 3.5-dia. holes
4.1 dia., oneconductor coaxial cable (length: 3 m)
Two, 4.5-dia. holes
5
F2LP-W
F2LP-W
F2LP-W50M
F2LP-W75M
91 dia. 76 dia.
Four, 7-dia. holes 5.5 dia., oneconductor coaxial cable (length: 3 m) 75 dia. 5.5 dia., one-conductor coaxial cable (length: 3 m)
50 dia.
3.5 radius
Amplifier Unit
F2LP-W100M F2LP-WK4-US
Mounting Holes
Two, M4 holes
Four, 7-dia. holes
100 dia.
5.5 dia., one-conductor coaxial cable (length: 3 m)
3.5 radius
6
F2LP-W
DC Solid State Output Stage Circuit Diagram
Note: 1. The load can be connected as follows:
F2LP-W
2.2
Load
47 V
Load 2. The maximum capacity of the load is 100 mA, 40 VDC. Main circuit of Sensor
Connections
Note: Shielding Conductor
Terminal 7 (internal circuit 0 V) can be grounded by grounding the Sensor, because this terminal is connected to the metal case of the Sensor. Sensor input terminals 7 and 8, transistor output terminals 10 and 11, power supply terminals 1, 2, and 3, and relay connecting terminals 4, 5, and 6 are insulated from one another.
100 VAC 200 VAC, 50/60 Hz
Precautions
Please read the following carefully to ensure effective and proper use of the F2LP-W. Model F2LP-W10M F2LP-W20M F2LP-W50M F2LP-W75M F2LP-W100M 100 100 150 200 300 Distance l 100 20 30 40 50 Distance m
Influence of Metals at Close Range The Sensor can malfunction if there is a moving
metal object around the Sensor. Keep metal objects away from the Sensor by at least the distances indicated in the following drawing and table. Moving metal object
m
l
l
7
F2LP-W
The Sensor mounted on a metal base can malfunction if there is a metal object close to the coil of the Sensor. Keep metal away from the coil by at least the distances indicated in the following drawings. F2LP-W10M Metal Metal 10 mm max. F2LP-W20M Metal
F2LP-W
Mutual Interference When using more than one Sensor, ground the ground terminals
of the Sensors and then separate the Sensors one another by at least the distances indicated in the following drawings. The distances in parentheses apply when the Sensors are set to different frequencies.
l1
Facing each other
Metal 19 mm max.
l2
In parallel
F2LP-W50M Metal Metal Model 11 mm max. F2LP-W10M F2LP-W20M F2LP-W50M F2LP-W75M
112 dia. min.
Facing (l 1) 500 (100) 500 (100) 500 (100) 750 (150) 1,000 (200)
Parallel (l 2) 500 (100) 500 (100) 500 (100) 750 (150) 1,000 (200)
F2LP-W75M F2LP-W100M
Metal
Metal 34 mm max. To mount the F2LP-W75M on a flange, open a hole of at least 112 dia. min.
Others Do not use the Sensor immediately after power is on, since the
Metal Sensor needs an interval of 1 to 2 seconds after power is on to function normally and sense objects. To maintain noise resistance when connecting a Sensor cable to the Amplifier Unit terminals, always use a cable with a conductor thickness of no more than 10 mm. 10 mm max.
Note:
F2LP-W100M
150 dia. min.
Metal
Metal
Note:
25 mm To mount the F2LP-W100M on a flange, open a hole of at least 150 dia.
Sensor Metal
Sensor cable
Amplifier Unit

Only one pulse (40 ms) will be output when the sensing object is stationary or if the sensing object is always present such as the case when line breakage is detected. When using the Sensor at a high level of sensitivity, be careful not to touch or come in contact with the Sensor because any contact with the sensing surface will be detected.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. D32-E1-2
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Systems Components Division H.Q. 28th Fl., Crystal Tower Bldg. 1-2-27, Shiromi, Chuo-ku, Osaka 540 Japan Phone: 06-949-6012 Fax: 06-949-6021 Printed in Japan 0997-0.5M (0590) a
8


▲Up To Search▲   

 
Price & Availability of F2LP-W

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X